LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250 Turbine flow meter

Model: LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250
Measuring diameter: pipe type: DN0.5~DN600;
Accuracy class: ± 0.2%, ± 0.5%, ± 1.0%;
Ambient temperature: - 20 ℃~+50 ℃;

EMAIL

LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250 Turbine flow meter 


Overview

LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250 Turbine flow meter  adopts double row LCD field display, which has the obvious advantages of compact mechanism, intuitive and clear reading, high reliability, no interference from external power, lightning resistance, low cost, etc.


Technical parameters of LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250 Turbine flow meter

Measuring diameter: pipe type: DN0.5~DN600;

Accuracy class: ± 0.2%, ± 0.5%, ± 1.0%;

Ambient temperature: - 20 ℃~+50 ℃;

Medium temperature: measuring liquid: - 20 ℃~+120 ℃;

Nominal pressure: 1.6 Mpa, 2.5 Mpa, 6.4 Mpa, 25 Mpa;

Explosion proof grade: ExdIIBT4;

Connection mode: threaded connection, clamp connection, flange connection, plug-in connection, etc;

Output function: pulse output, 4~20mA two-wire current output, with RS485 communication interface.


Features of LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250 Turbine flow meter

High precision, generally up to ± 1% F · S, ± 0.5% F · S, high precision type up to ± 0.2% F · S;

Good repeatability, short-term repeatability can reach 0.05%~0.2%. It is precisely because of its good repeatability, such as high accuracy can be obtained through regular calibration or online calibration, and it is the preferred flowmeter in trade settlement;

Output pulse frequency signal, suitable for total quantity measurement and computer connection, no zero drift, strong anti-interference capability;

It can obtain high frequency signal (3-4kHz) with strong signal resolution;

The range is wide, the medium and large caliber can reach 1:20, and the small caliber can reach 1:10;

Compact and light structure, convenient installation and maintenance, and large circulation capacity.


Installation matters of LWGY-100 LWGY-125 LWGY-150 LWGY-200 LWGY-250 Turbine flow meter

1. Before putting into operation, set the instrument coefficient and carefully check to ensure that the flowmeter is connected correctly and grounded well before power transmission;

2. The flowmeter shall be cleaned, inspected and re calibrated regularly. For the flowmeter with lubricating oil or cleaning fluid injection inlet, lubricating oil or cleaning fluid shall be injected regularly according to the requirements of the manual to maintain the impeller in good operation;

3. Monitor the condition of the display instrument, evaluate the reading of the display instrument, and timely check if there is any abnormality;

4. Keep the filter unblocked. The blockage of the filter can be judged from the increase of the reading difference of the pressure gauge at its inlet and outlet, and the blockage can be eliminated in time;